RTView Enterprise 5.1

If you are upgrading from a previous version and also have modified the RTViewCentral/projects/rtview-server/central.properties file, you should not modify the central.properties file under rtvapm/appmon/conf. Instead, add those properties in the Configuration Application CUSTOM PROPERTIES tab.
If you are collecting Syslog events with Solace Event Module, copy RTViewDataServerSolace/rtvapm/solmon/soleventmodule/config/soleventmodule.properties to your new installation. Additionally, if you made changes in logging, copy RTViewDataServerSolace/rtvapm/solmon/soleventmodule/config/log4j2.properties to your new installation.
The rtview-manager directory is not typically customized in RTViewCentral. However, in the case where this directory was customized, upgrading users should re-apply their changes to the new rtview-manager project and not just override the directory with the old version of the rtview-manager directory.
If you are upgrading from a previous version and have enabled EM Integration, but left Announce this RTView Data Server to the Central Server as false, youl need to go into the RTView Configuration Application and set it to false again as the default has changed from false to true.
For upward compatibility, if the projects\sl.log4j.properties file is not found, the rtvapm\common\conf\sl.log4j.properties file will be used instead. However, users upgrading from previous versions who have modified the logging settings should apply their logging changes to the sl.log4j.properties file in projects instead of the copy under rtvapm\common\conf in order to make it easier to upgrade to future releases.

Alert Notification

In previous releases, any notification other than executing the my_alert_actions scripts had to be configured on the CUSTOM PROPERTIES tab of the RTView Configuration Application. If you are running a project configured with a previous release that has alert notifications defined in the CUSTOM PROPERTIES tab, they will continue to work as they did before with no changes. However, if you want to use the new Alert Notification configuration page, you will need to first delete the CUSTOM PROPERTIES for alert notifications, then recreate them in the Alert Notification page. Otherwise, the CUSTOM PROPERTIES will override the settings in the Alert Notification page.

Solution Package for Solace

The database table schemas in the rtvapm\solmon\dbconfig directory have been updated to include all updated table schemas. To upgrade, drop the following database tables from the RTVHISTORY database:

SOL_BRIDGE_STATS
SOL_CSPF_NEIGHBOR
SOL_VPNS
SOL_CLIENT_STATS
SOL_CSPF_NEIGHBOR

Recreate the database tables using the appropriate table creation SQL sentence for your supported platform which are in the rtvapm\solmon\dbconfig directory.

Return to Download, Install, Register and Upgrade RTViewCentral.