Modify Default Polling Rates for Solace Caches

To modify the default polling rate settings for Solace caches, perform the following:

Open the RTView Configuration Application and go to Solace>DATA COLLECTION tab.

cui_solace_Pollrates.gif

Poll Rate: Collection period in seconds. This configuration element affects the following caches: SolEndpointStats, SolEndpoints, SolClients, SolClientStats, SolBridges, SolAppliances, SolBridgeStats, SolApplianceInterfaces and SolApplianceMessageSpool.

Poll Rate Large: Slower collection period in seconds for monitoring data that can impact the performance of the monitoring systems if the rate is very fast. This configuration element affects the following caches: SolCspfNeighbors, SolApplicances and SolEnvironmentSensors.

Solace Event Module Alerts Clear Time: Defines the time interval, in seconds, when non-clearable event alerts from the Solace Event Module will be dismissed from the monitor.